Molecular models and example status =================================== A molecular formula does not uniquely specify a TROVE model. Coordinates, frame, kinetic representation, surface parameters, and basis settings must be considered together. This catalogue starts with four models that help explain those choices; the broader historical coverage is in :doc:`molecules`. The entries below distinguish code/input inspection from numerical validation. Production ExoMol settings can require substantially more resources than a teaching example. Hydrogen sulfide: H2S --------------------- The :doc:`basic_functions_example` uses ``MOLTYPE XY2``, ``C2v(M)`` symmetry, valence coordinates ``R-ALPHA``, the ``BISECT-Z`` frame, and a rigid reference configuration. Its KEO is the built-in compact analytic ``KINETIC_XY2_EKE_BISECT_COMPACT_RIGID`` representation. The nuclear mass order is S, H, H. This is a bent-coordinate example with integration bounds away from the linear singularities. The supplied input includes the ``POTEN_XY2_TYUTEREV`` parameter list and an ``XY2_PQ_COEFF`` dipole parameter list. The tutorial tests the kinetic constructor and small-basis energy calculation; it does not establish an intensity benchmark or reproduce a production ExoMol line list. See the tutorial for the precise numerical validation scope and commands. The associated code is in ``mol_xy2.f90``, ``kin_xy2.f90``, and ``pot_xy2.f90``. The downloadable input is :download:`H2S_EKE_basic-functions_step1.inp `. Its small primitive and contracted cutoffs are teaching settings, not a statement of spectroscopic convergence. Silylene: SiH2 / CATS --------------------- The repository's ``inputs/SiH2`` directory contains CATS inputs for steps 1 and 2, step 3 at several J values, and a step-4 intensity calculation. The step-1 configuration uses ``MOLTYPE XY2``, ``C2v(M)``, ``COORDS LINEAR``, ``TRANSFORM R-RHO-Z``, and ``REFER-CONF NON-RIGID``. Here ``LINEAR`` denotes linearised coordinates; it does not mean that the molecule is linear. The mass order is Si, H, H. The PEF is ``POTEN_XY2_MORSE_COS``. The input specifies ``KinOrder 6`` and ``PotOrder 8`` and uses Numerov primitive functions. This non-rigid, linearised-coordinate model is different from the rigid-reference H2S SPAR tutorial, even though both use the XY2 molecular implementation. The `CATS publication `__ describes the production calculation. The manual also supplies :download:`a SiH2 example `; its settings must not be assumed identical to every CATS stage. These inputs have been inspected for configuration, but have not been rerun as part of this documentation update. Later stages require the checkpoints produced by the earlier stages. Thioformaldehyde: H2CS / MOTY ----------------------------- The MOTY model [23MeOwTe]_ uses the ``ZXY2`` molecular implementation and ``R-THETA-TAU`` coordinates with a rigid reference configuration. Its six coordinates comprise three bond lengths, two angles, and a torsion. See :doc:`kinetic` for the function ordering and :doc:`frames` for the embedding. Do not infer the nuclear mass order from the molecular formula; retain the model's ``ZMAT`` order. The `MOTY model archive `__ and the supplementary material of [23MeOwTe]_ provide the model provenance and kinetic derivation. The inspected MOTY input requests an external kinetic checkpoint. The model page also links the companion ``kinetic.chk``. Obtain that file together with the input and check its function mapping and derivation conventions before running it. The page identifies the original executable as ``j-trove2509.x (2022)``; compatibility with a later revision must be checked. This documentation update does not claim a reproduced MOTY spectrum. The repository also contains ``inputs/H2CS/H2CS_Andrey_PES2_rigid_01b_basic.inp`` with ``POTEN_H2CS_DAMP``, while the downloadable :download:`H2CS_zxy2_morse_cos_step1.inp ` uses ``POTEN_ZXY2_MORSE_COS``. These are different model specifications; sharing a formula and coordinate family does not make the surfaces interchangeable. Both remain reference inputs pending complete numerical validation and dependency packaging. Phosphine: PH3 with external SPAR KEOs -------------------------------------- The :doc:`spar_xy3` page uses ``MOLTYPE XY3``, ``C3v(M)`` symmetry, the SPAR coordinates ``R-SYMPHI-BETA`` :math:`(r_1,r_2,r_3,s_4,s_5,\beta)`, and a rigid reference configuration. The nuclear mass order is P, H, H, H. The KEO is not built in; it is generated outside TROVE in two forms: a 1D-based operator (Taylor expansion of order 4 in :math:`(s_4,s_5)`, exact in the bond lengths and :math:`\beta`) and a 2D-based operator (exact in :math:`(s_4,s_5)`, with 2D integrals read from ``keo_2d_s4s5.chk``). Both ``kinetic.chk`` files use the mass-factorised ``BASIC-FUNCTION MASS`` format. The potential is ``poten_xy3_morbid_10`` with the parameters given in the inputs. The downloadable 1D-based inputs are at polyad 14; polyad-6 examples for both the 1D-based (``inputs/PH3/1D_SPAR``, :math:`N=8`) and 2D-based (``inputs/PH3/2D_exact``) routes are also in ``inputs/PH3``. Numerical status: J = 0--4 energies and symmetry labels of the 1D-based model were compared with a calculation using the built-in linearised KEO; J = 0 and 1 were computed with the 2D-based model at polyads 6 and 14. Intensities have not been validated. The code is in ``mol_xy3.f90`` (coordinates and symmetry) and ``perturbation.f90`` (2D integration). Adding another entry -------------------- Use the following information for each model: * Formula, isotopologue, electronic-state scope, citation, and model name. * Molecular family, symmetry, atom order, masses, coordinates, and frame. * KEO approximation and source; potential and property functional forms. * Full input and all external parameters, checkpoints, or compiled modules. * Primitive and contracted basis settings and numerical integration bounds. * Stage dependencies, representative resource use, and expected outputs. * Validation state and evidence: inspected, run complete, numerically compared, or tutorial ready; specify the tested observables and tolerances. Retain the original production specification when deriving a smaller example, and state every change that affects the physical model or its numerical approximation.