SPAR operator files and conventions
A BASIC-FUNCTION block defines the coordinate functions. The operator
file supplies their coefficients and index tuples. Both are needed to
reconstruct the model. TROVE has several checkpoint readers, selected by
the input options; a filename ending in .chk does not identify its format.
KEO components
The kinetic checkpoint contains four consecutive sections:
Section |
Indices |
Meaning |
|---|---|---|
|
|
Two vibrational modes |
|
|
Two body-fixed rotational axes (1, 2, 3) |
|
|
Vibrational mode followed by rotational axis |
Pseudopotential |
|
Scalar contribution; retain the file’s placeholder fields |
In the mode-indexed KEO reader, a data record has the layout:
k1 k2 term grid coefficient l1 l2 ... lD
In the mass-factorised reader the layout is:
k1 k2 term grid coefficient l0 l1 l2 ... lD
term is local to the component. Keep component records together.
grid is 0 for a rigid-reference file; non-rigid grid handling requires
the matching reference-configuration setup. A zero coordinate index selects
the constant function. In the mass-factorised format l0 is a positive
atom index in the ZMAT mass order; it is not a coordinate exponent.
Each section has a header and ends with a sentinel record beginning with
987654321. Preserve the remaining sentinel fields as well: the reader
reads the whole record before checking the sentinel. Keep the final
threshold record and footer, where present. The abbreviated tables in the
paper omit some native checkpoint fields and are not complete files.
Units and mass factors
The ordinary mode-indexed reader uses the supplied coefficients directly in TROVE’s internal energy convention. A checkpoint written by the matching TROVE calculation is the safest starting point for this route.
The mass-factorised reader multiplies each coefficient by an internal
conversion factor divided by mass(l0). The factor in fields.f90 is
with the physical constants in TROVE’s own unit convention. The conversion is consistent with distances in angstroms, angular coordinates in radians, nuclear masses in atomic mass units, and output energies in \(\mathrm{cm}^{-1}\). Do not multiply a saved internal-unit checkpoint by this factor a second time. Compare a reconstructed operator at several geometries before using converted coefficients for a spectrum.
Selecting a reader
An external mode-indexed KEO commonly uses the following checkpoint option:
CHECK_POINT
kinetic read with_modes
END
This is an excerpt, not a complete restart specification. Pair it with the
appropriate BASIC-FUNCTION block, KINETIC settings, coordinates,
frame, and basis. BASIC-FUNCTION MASS selects the additional mass column.
See Checkpoints for the other checkpoint objects and the staged
TROVE workflow. Reusing wavefunctions or matrix elements requires compatible
dimensions and conventions as well as compatible files.
A BASIC-FUNCTION block (KINETIC or MASS) selects the mode-indexed
reader by itself, so kinetic read is sufficient and with_modes is
optional. The PH3 inputs of PH3: 1D-based and 2D-based SPAR kinetic energy operators use kinetic read.
Do not retain KINETIC COMPACT when intending to read an external file:
at this revision that option unconditionally changes KINETIC READ to
SAVE for the built-in construction route. In the H2S round-trip test,
the entire built-in KINETIC block is removed, the explicit function
library is retained, and kinetic read with_modes is specified after
the CONTROL block. The saved kinetic.chk is copied into the fresh
run directory. This exercises the external reader instead of rebuilding
the operator. See H2S: a compact SPAR kinetic operator.
Two-dimensional KEO integrals
A 2D-based KEO (Eq. (2) of SPAR: operator representations) needs a second file,
keo_2d_s4s5.chk, with the integrals of its 2D functions over modes 4
and 5. TROVE reads it whenever it exists in the working directory; there is
no input keyword. The element
me2d(iop4, iop5, i4, i5, v4, v4', v5, v5') is the integral
\(I^{(o_4o_5)}_{k_4k_5}(v_4v_4';v_5v_5')\) defined on PH3: 1D-based and 2D-based SPAR kinetic energy operators,
with \(o_4=\) iop4, \(o_5=\) iop5, \(k_4=\) i4 and
\(k_5=\) i5.
iop4 and iop5 (0–3) give the placement of the derivatives, i4 and
i5 are the labels of the 2D function used in columns l4 and l5 of
kinetic.chk, and v4, v4', v5, v5' are harmonic-oscillator
quantum numbers. Two formats are recognised from the first bytes of the
file.
The ASCII format, written by default, looks like this:
keo_2d_s4s5 2D (s4,s5) integrals of the KEO terms of modes 4 and 5
8 6 1382976 <- kmax, vmax, number of entries
mode=exact ft=0.2865833376039929 rmax=2.45 n_rho=80 n_theta=96 rank=63
iop4 iop5 i4 i5 v4 v4' v5 v5' value
0 0 0 0 0 0 0 0 9.9999999999999356e-01
...
End of keo_2d_s4s5
The first line must start with keo_2d_s4s5. The second gives
\(k_{\max}\), \(v_{\max}\) and the number \(N\) of entries. The
third line is free text; the generator records its parameters there. The
fourth line is a column header. Then follow \(N\) lines
iop4 iop5 i4 i5 v4 v4' v5 v5' value for the non-zero elements, and the
line End of keo_2d_s4s5. Missing elements are zero. Values with 17
significant digits reproduce the double-precision numbers exactly. TROVE
stops if an entry lies outside the ranges in the header or if End does
not follow the \(N\) entries.
The binary format (exact_2d_keo.py --binary) is a stream file without
record markers. It contains two 4-byte integers, \(k_{\max}\) and
\(v_{\max}\), followed by the 8-byte real array
me2d(0:3, 0:3, 0:kmax, 0:kmax, 0:vmax, 0:vmax, 0:vmax, 0:vmax) in Fortran
order and native byte order.
For PH3 with \(k_{\max}=8\) and \(v_{\max}=6\), the ASCII file has
1 382 976 entries (about 83 MB) and the binary file is 25 MB; TROVE gave the
same energies with both. A kinetic.chk whose l4, l5 columns hold
2D labels is meaningful only together with the keo_2d_s4s5.chk generated
with it. The consistency checks performed by TROVE, and those left to the
user, are listed on PH3: 1D-based and 2D-based SPAR kinetic energy operators.
Potential and dipole files
The potential and external-property readers have their own record formats and function-index conventions. External-property records include a component index; the meaning of that component depends on the chosen body-fixed frame and property representation. The model must specify that mapping explicitly. The compact tables in the SPAR supplementary material document the model coefficients, while SPAR input syntax and migration describes the current TROVE constructor. Neither replaces a complete native checkpoint example.
Validation before reuse
Check atom, coordinate, and component order against the derivation.
Check every tuple against its function library and mass convention.
Evaluate the reconstructed functions at non-singular geometries and compare them with independent analytic expressions or reference data.
Run a small calculation from a clean directory. Inspect the program’s completion message and selected levels; a zero process exit status alone does not prove that a Fortran program completed.
Check a nonzero-J case before claiming rotational/Coriolis validation, and a transition observable before claiming intensity validation.
The H2S example tests the explicit kinetic-function library and the ordinary mode-indexed KEO checkpoint reader. It is separate from validation of the mass-factorised and external PEF/DMF readers.